EATON MOELLER® SERIES DILM CONTACTOR 277018

Eaton Moeller® series DILM CoEaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 7.5 kW, 1 N/O, RDC 24: 24 – 27 V DC, DC operation, Screw terminals DILM17-10(RDC24)ntactor, 3 pole, 380 V 400 V Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 7.5 kW, 1 N/O, RDC 24: 24 – 27 V DC, DC operation, Screw terminals DILM17-10(RDC24)7.5 kW, 1 N/O, RDC 24: 24 – 27 V DC, DC operation, Screw terminals DILM17-10(RDC24)

Description

General specifications Product Name Eaton Moeller® series DILM contactor
Catalog Number 277018
Model Code DILM17-10(RDC24)
EAN 4015082770181
Product Length/Depth 97 mm
Product Height 85 mm
Product Width 45 mm
Product Weight 0.534 kg
Certifications UL 60947-4-1 UL CSA-C22.2 No. 60947-4-1-14 VDE 0660 IEC/EN 60947 UL Category Control No.: NLDX CSA CSA File No.: 012528 IEC/EN 60947-4-1 CSA Class No.: 2411-03, 3211-04 CE UL File No.: E29096
Catalog Notes Contacts according to EN 50012
Product specifications Terminal capacity (flexible with ferrule) 1 x (0.75 – 2.5) mm², Control circuit cables 1 x (0.75 – 16) mm², Main cables 2 x (0.75 – 10) mm², Main cables 2 x (0.75 – 2.5) mm², Control circuit cables
Rated operational current for specified heat dissipation (In) 18 A
10.11 Short-circuit rating Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Rated operational power at AC-3, 380/400 V, 50 Hz 7.5 kW
Conventional thermal current ith (3-pole, enclosed) 32 A
Rated operational power at AC-4, 380/400 V, 50 Hz 4.5 kW
Rated operational current (Ie) at AC-4, 440 V 10 A
Rated control supply voltage (Us) at AC, 50 Hz – min 0 V
Conventional thermal current ith at 60°C (3-pole, open) 35 A
10.4 Clearances and creepage distances Meets the product standard’s requirements.
Number of contacts (normally closed) as main contact 0
Short-circuit current rating (high fault at 480 V) 125/70 A, Class J, max. Fuse, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA) 10/100 kA, Fuse, SCCR (UL/CSA) 10/65 kA, CB, SCCR (UL/CSA)
Conventional thermal current ith at 55°C (3-pole, open) 37 A
Rated operational power (NEMA) 7.4 kW
10.2.3.1 Verification of thermal stability of enclosures
Ambient storage temperature – min 40 °C
Fitted with: Suppressor circuit in actuating electronics
Rated breaking capacity at 380/400 V 170 A
Short-circuit current rating (basic rating) 125 A, max. Fuse, SCCR (UL/CSA) 125 A, max. CB, SCCR (UL/CSA) 5 kA, SCCR (UL/CSA)
Rated control supply voltage (Us) at AC, 50 Hz – max
Rated breaking capacity at 660/690 V 120 A
Rated operational current (Ie) at DC-1, 220 V
Special purpose rating of elevator control 9.6 A, 240 V 60 Hz 3-ph, (UL/CSA) 10 HP, 600 V 60 Hz 3-ph, (UL/CSA) 11 A, 200 V 60 Hz 3-ph, (UL/CSA) 3 HP, 200 V 60 Hz 3-ph, (UL/CSA) 11 A, 480 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA) 11 A, 600 V 60 Hz 3-ph, (UL/CSA) 3 HP, 240 V 60 Hz 3-ph, (UL/CSA)
Ambient operating temperature – max 60 °C
Assigned motor power at 115/120 V, 60 Hz, 1-phase 2 HP
Rated operational power at AC-4, 440 V, 50 Hz 5.5 kW
Electrical connection type of main circuit Screw connection
Power consumption (sealing) at DC 0.9 W
Number Of Poles Three-pole
Ambient operating temperature – min -25 °C
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
10.3 Degree of protection of assemblies
Application Contactors for Motors
Operating frequency 5000 mechanical Operations/h (DC operated)
Voltage type DC
Short-circuit protection rating (type 1 coordination) at 400 V 63 A gG/gL
Product category Contactors
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
Rated operational power at AC-3, 690 V, 50 Hz 11 kW
Heat dissipation capacity Pdiss 0 W
Assigned motor power at 460/480 V, 60 Hz, 3-phase 10 HP
Special purpose rating of tungsten incandescent lamps 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Rated operational current (Ie) at AC-4, 500 V
Rated operational power at AC-3, 240 V, 50 Hz
Operating voltage at AC, 60 Hz – max 690 V
Terminal capacity (solid/stranded AWG) 18 – 14, Control circuit cables Single 18 – 6, double 18 – 8, Main cables
10.9.2 Power-frequency electric strength Is the panel builder’s responsibility.
Degree of protection IP00
Overvoltage category III
Ambient storage temperature – max 80 °C
Pollution degree 3
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V 40 A
Rated impulse withstand voltage (Uimp) 8000 V AC
Connection Screw terminals
Operating voltage at AC, 60 Hz – min 24 V
Tightening torque 1.2 Nm, Screw terminals, Control circuit cables 3.2 Nm, Screw terminals, Main cables
Rated operational power at AC-4, 660/690 V, 50 Hz 6.5 kW
Frame size FS2
Conventional thermal current ith (1-pole, enclosed) 80 A
Rated operational current (Ie) at AC-3, 660 V, 690 V 12 A
10.2.2 Corrosion resistance
10.2.4 Resistance to ultra-violet (UV) radiation
10.2.7 Inscriptions
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
Number of contacts (normally open contacts) 1
Short-circuit protection rating (type 2 coordination) at 400 V 35 A gG/gL
Special purpose rating of ballast electrical discharge lamps 40 A (480V 60Hz 3phase, 277V 60Hz 1phase) 40 A (600V 60Hz 3phase, 347V 60Hz 1phase)
Number of auxiliary contacts (normally open contacts)
Special purpose rating of definite purpose rating 18 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 108 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Rated operational power at AC-3, 500 V, 50 Hz 12 kW
Shock resistance 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5.3 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 6.9 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 3.5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
Rated operational current (Ie) at DC-1, 110 V
Assigned motor power at 230/240 V, 60 Hz, 3-phase 5 HP
Drop-out voltage At least smoothed two-phase bridge rectifier or three-phase rectifier 0.6 – 0.15 x UC, DC operated
Resistance per pole 2.7 mΩ
Ambient operating temperature (enclosed) – min 25 °C
Stripping length (control circuit cable) 10 mm
Operating voltage at AC, 50 Hz – max
10.12 Electromagnetic compatibility
Special purpose rating of refrigeration control (CSA only) 40 A, FLA 480 V 60 Hz 3phase; (CSA) 180 A, LRA 600 V 60 Hz 3phase; (CSA) 30 A, FLA 600 V 60 Hz 3phase; (CSA) 240 A, LRA 480 V 60 Hz 3phase; (CSA)
10.2.5 Lifting
Stripping length (main cable)
Ambient operating temperature (enclosed) – max
Special purpose rating of resistance air heating 40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Rated control supply voltage (Us) at DC – min
Short-circuit current rating (high fault at 600 V) 125/70 A, Class J, max. Fuse, SCCR (UL/CSA) 10/22 kA, CB, SCCR (UL/CSA) 10/100 kA, Fuse, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA)
10.8 Connections for external conductors
Number of main contacts (normally open contact)
Rated breaking capacity at 220/230 V
Screw size M3.5, Terminal screw, Control circuit cables M5, Terminal screw, Main cables
Rated operational current (Ie) at AC-4, 400 V
Short-circuit protection rating (type 2 coordination) at 690 V
Assigned motor power at 575/600 V, 60 Hz, 3-phase 15 HP
Protection Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated operational power at AC-3, 440 V, 50 Hz 10.5 kW
Terminal capacity (stranded) 1 x 16 mm², Main cables
Rated breaking capacity at 500 V
Rated operational power at AC-3, 415 V, 50 Hz 10 kW
Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Emitted interference According to EN 60947-1
Connection to SmartWire-DT Yes In conjunction with DIL-SWD SmartWire DT contactor module
Static heat dissipation, non-current-dependent Pvs
Rated control supply voltage (Us) at DC – max 27 V
10.9.3 Impulse withstand voltage
Utilization category AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Rated operational current (Ie) at AC-3, 440 V
10.5 Protection against electric shock
Safe isolation 440 V AC, Between coil and contacts, According to EN 61140 440 V AC, Between the contacts, According to EN 61140
Operating voltage at AC, 50 Hz – min
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.9.4 Testing of enclosures made of insulating material
Heat dissipation per pole, current-dependent Pvid 0.7 W
Actuating voltage RDC 24: 24 – 27 V DC
Switching time (DC operated, make contacts, opening delay) – max 30 ms
Switching capacity (auxiliary contacts, general use) 10 A, 600 V AC, (UL/CSA) 1 A, 250 V DC, (UL/CSA)
Switching time (DC operated, make contacts, closing delay) – max 47 ms
Rated operational current (Ie) at AC-4, 660 V, 690 V 8 A
Equipment heat dissipation, current-dependent Pvid 2.1 W
Assigned motor power at 200/208 V, 60 Hz, 3-phase
Pick-up voltage 24 – 27 V DC (RDC 24) 0.7 – 1.2 V DC x Uc
Suitable for Also motors with efficiency class IE3
Conventional thermal current ith at 40°C (3-pole, open)
Terminal capacity (solid) 1 x (0.75 – 16) mm², Main cables 2 x (0.75 – 2.5) mm², Control circuit cables 1 x (0.75 – 4) mm², Control circuit cables 2 x (0.75 – 10) mm², Main cables
Number of auxiliary contacts (normally closed contacts)
Interference immunity
10.2.3.2 Verification of resistance of insulating materials to normal heat
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Lifespan, mechanical 10,000,000 Operations (DC operated)
Short-circuit protection rating (type 1 coordination) at 690 V 50 A gG/gL
Rated making capacity up to 690 V (cos phi to IEC/EN 60947) 238 A
Rated operational power at AC-4, 240 V, 50 Hz 3 kW
Rated operational power at AC-4, 500 V, 50 Hz 6 kW
Rated operational current (Ie) at DC-1, 60 V
Rated operational power at AC-4, 220/230 V, 50 Hz 2.5 kW
Rated operational voltage (Ue) at AC – max
Rated control supply voltage (Us) at AC, 60 Hz – min
10.7 Internal electrical circuits and connections
Power consumption (pick-up) at DC 12 W
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Switching capacity (main contacts, general use) 40 A, Maximum motor rating (UL/CSA)
Conventional thermal current ith at 50°C (3-pole, open) 38 A
Rated operational current (Ie) at AC-3, 500 V
Assigned motor power at 230/240 V, 60 Hz, 1-phase 3 HP
Screwdriver size 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver 2, Terminal screw, Pozidriv screwdriver
Duty factor 100 %
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
Conventional thermal current ith of main contacts (1-pole, open) 88 A
Rated control supply voltage (Us) at AC, 60 Hz – max
Arcing time 10 ms
Rated operational power at AC-4, 415 V, 50 Hz 5 kW
Switching capacity (auxiliary contacts, pilot duty) A600, AC operated (UL/CSA) P300, DC operated (UL/CSA)
Rated insulation voltage (Ui)
Altitude Max. 2000 m
Catalogs  Product Range Catalog Switching and protecting motors
 SmartWire-DT Catalog
 Product overview for machinery
 Switching and protecting motors – catalog
Certification reports  0000SPC-571
Characteristic curve  eaton-contactors-component-dilm-characteristic-curve-003.eps
 2100DIA-7
 210U038
 2100DIA-8
 eaton-contactors-switch-dilm-characteristic-curve.eps
 eaton-contactors-short-time-loading-dilm-characteristic-curve.eps
 eaton-contactors-switch-dilm-characteristic-curve-002.eps
 210U039
Drawings  eaton-contactors-mounting-dilm-dimensions-002.eps
 eaton-contactors-contact-dilm-dimensions-002.eps
 210N018
 eaton-contactors-dilm-dimensions.eps
 210X202
 eaton-contactors-mounting-dilm-dimensions.eps
 210N017
 210T014
 eaton-contactors-dilm-3d-drawing-009.eps
 210I192
 eaton-general-ie-ready-dilm-contactor-standards.eps
eCAD model  DA-CE-ETN.DILM17-10(RDC24)
Installation instructions  IL03407014Z2018_07
 IL03407014Z
mCAD model  DA-CS-dil_m17_38
 DA-CD-dil_m17_38
PEP Eco-passport  EATO-00026-V01.01-EN
Specifications and datasheets  Eaton Specification Sheet – 277018
System overview  210O154
 eaton-contactors-dilm-contactor-system-overview.eps
Wiring diagrams  eaton-contactors-contact-dilm-wiring-diagram.eps
 210S026
Date Thu Jul 20 2023