Eaton Moeller® series DILM CoEaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 7.5 kW, 1 N/O, RDC 24: 24 – 27 V DC, DC operation, Screw terminals DILM17-10(RDC24)ntactor, 3 pole, 380 V 400 V Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 7.5 kW, 1 N/O, RDC 24: 24 – 27 V DC, DC operation, Screw terminals DILM17-10(RDC24)7.5 kW, 1 N/O, RDC 24: 24 – 27 V DC, DC operation, Screw terminals DILM17-10(RDC24)
Description
General specifications | Product Name | Eaton Moeller® series DILM contactor |
Catalog Number | 277018 | |
Model Code | DILM17-10(RDC24) | |
EAN | 4015082770181 | |
Product Length/Depth | 97 mm | |
Product Height | 85 mm | |
Product Width | 45 mm | |
Product Weight | 0.534 kg | |
Certifications | UL 60947-4-1 UL CSA-C22.2 No. 60947-4-1-14 VDE 0660 IEC/EN 60947 UL Category Control No.: NLDX CSA CSA File No.: 012528 IEC/EN 60947-4-1 CSA Class No.: 2411-03, 3211-04 CE UL File No.: E29096 | |
Catalog Notes | Contacts according to EN 50012 | |
Product specifications | Terminal capacity (flexible with ferrule) | 1 x (0.75 – 2.5) mm², Control circuit cables 1 x (0.75 – 16) mm², Main cables 2 x (0.75 – 10) mm², Main cables 2 x (0.75 – 2.5) mm², Control circuit cables |
Rated operational current for specified heat dissipation (In) | 18 A | |
10.11 Short-circuit rating | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | |
Rated operational power at AC-3, 380/400 V, 50 Hz | 7.5 kW | |
Conventional thermal current ith (3-pole, enclosed) | 32 A | |
Rated operational power at AC-4, 380/400 V, 50 Hz | 4.5 kW | |
Rated operational current (Ie) at AC-4, 440 V | 10 A | |
Rated control supply voltage (Us) at AC, 50 Hz – min | 0 V | |
Conventional thermal current ith at 60°C (3-pole, open) | 35 A | |
10.4 Clearances and creepage distances | Meets the product standard’s requirements. | |
Number of contacts (normally closed) as main contact | 0 | |
Short-circuit current rating (high fault at 480 V) | 125/70 A, Class J, max. Fuse, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA) 10/100 kA, Fuse, SCCR (UL/CSA) 10/65 kA, CB, SCCR (UL/CSA) | |
Conventional thermal current ith at 55°C (3-pole, open) | 37 A | |
Rated operational power (NEMA) | 7.4 kW | |
10.2.3.1 Verification of thermal stability of enclosures | ||
Ambient storage temperature – min | 40 °C | |
Fitted with: | Suppressor circuit in actuating electronics | |
Rated breaking capacity at 380/400 V | 170 A | |
Short-circuit current rating (basic rating) | 125 A, max. Fuse, SCCR (UL/CSA) 125 A, max. CB, SCCR (UL/CSA) 5 kA, SCCR (UL/CSA) | |
Rated control supply voltage (Us) at AC, 50 Hz – max | ||
Rated breaking capacity at 660/690 V | 120 A | |
Rated operational current (Ie) at DC-1, 220 V | ||
Special purpose rating of elevator control | 9.6 A, 240 V 60 Hz 3-ph, (UL/CSA) 10 HP, 600 V 60 Hz 3-ph, (UL/CSA) 11 A, 200 V 60 Hz 3-ph, (UL/CSA) 3 HP, 200 V 60 Hz 3-ph, (UL/CSA) 11 A, 480 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA) 11 A, 600 V 60 Hz 3-ph, (UL/CSA) 3 HP, 240 V 60 Hz 3-ph, (UL/CSA) | |
Ambient operating temperature – max | 60 °C | |
Assigned motor power at 115/120 V, 60 Hz, 1-phase | 2 HP | |
Rated operational power at AC-4, 440 V, 50 Hz | 5.5 kW | |
Electrical connection type of main circuit | Screw connection | |
Power consumption (sealing) at DC | 0.9 W | |
Number Of Poles | Three-pole | |
Ambient operating temperature – min | -25 °C | |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | |
10.2.6 Mechanical impact | ||
10.3 Degree of protection of assemblies | ||
Application | Contactors for Motors | |
Operating frequency | 5000 mechanical Operations/h (DC operated) | |
Voltage type | DC | |
Short-circuit protection rating (type 1 coordination) at 400 V | 63 A gG/gL | |
Product category | Contactors | |
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V | ||
Rated operational power at AC-3, 690 V, 50 Hz | 11 kW | |
Heat dissipation capacity Pdiss | 0 W | |
Assigned motor power at 460/480 V, 60 Hz, 3-phase | 10 HP | |
Special purpose rating of tungsten incandescent lamps | 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) | |
Rated operational current (Ie) at AC-4, 500 V | ||
Rated operational power at AC-3, 240 V, 50 Hz | ||
Operating voltage at AC, 60 Hz – max | 690 V | |
Terminal capacity (solid/stranded AWG) | 18 – 14, Control circuit cables Single 18 – 6, double 18 – 8, Main cables | |
10.9.2 Power-frequency electric strength | Is the panel builder’s responsibility. | |
Degree of protection | IP00 | |
Overvoltage category | III | |
Ambient storage temperature – max | 80 °C | |
Pollution degree | 3 | |
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 40 A | |
Rated impulse withstand voltage (Uimp) | 8000 V AC | |
Connection | Screw terminals | |
Operating voltage at AC, 60 Hz – min | 24 V | |
Tightening torque | 1.2 Nm, Screw terminals, Control circuit cables 3.2 Nm, Screw terminals, Main cables | |
Rated operational power at AC-4, 660/690 V, 50 Hz | 6.5 kW | |
Frame size | FS2 | |
Conventional thermal current ith (1-pole, enclosed) | 80 A | |
Rated operational current (Ie) at AC-3, 660 V, 690 V | 12 A | |
10.2.2 Corrosion resistance | ||
10.2.4 Resistance to ultra-violet (UV) radiation | ||
10.2.7 Inscriptions | ||
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | ||
Number of contacts (normally open contacts) | 1 | |
Short-circuit protection rating (type 2 coordination) at 400 V | 35 A gG/gL | |
Special purpose rating of ballast electrical discharge lamps | 40 A (480V 60Hz 3phase, 277V 60Hz 1phase) 40 A (600V 60Hz 3phase, 347V 60Hz 1phase) | |
Number of auxiliary contacts (normally open contacts) | ||
Special purpose rating of definite purpose rating | 18 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 108 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) | |
Rated operational power at AC-3, 500 V, 50 Hz | 12 kW | |
Shock resistance | 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5.3 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 6.9 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 3.5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms | |
Rated operational current (Ie) at DC-1, 110 V | ||
Assigned motor power at 230/240 V, 60 Hz, 3-phase | 5 HP | |
Drop-out voltage | At least smoothed two-phase bridge rectifier or three-phase rectifier 0.6 – 0.15 x UC, DC operated | |
Resistance per pole | 2.7 mΩ | |
Ambient operating temperature (enclosed) – min | 25 °C | |
Stripping length (control circuit cable) | 10 mm | |
Operating voltage at AC, 50 Hz – max | ||
10.12 Electromagnetic compatibility | ||
Special purpose rating of refrigeration control (CSA only) | 40 A, FLA 480 V 60 Hz 3phase; (CSA) 180 A, LRA 600 V 60 Hz 3phase; (CSA) 30 A, FLA 600 V 60 Hz 3phase; (CSA) 240 A, LRA 480 V 60 Hz 3phase; (CSA) | |
10.2.5 Lifting | ||
Stripping length (main cable) | ||
Ambient operating temperature (enclosed) – max | ||
Special purpose rating of resistance air heating | 40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) | |
Rated control supply voltage (Us) at DC – min | ||
Short-circuit current rating (high fault at 600 V) | 125/70 A, Class J, max. Fuse, SCCR (UL/CSA) 10/22 kA, CB, SCCR (UL/CSA) 10/100 kA, Fuse, SCCR (UL/CSA) 50/32 A, max. CB, SCCR (UL/CSA) | |
10.8 Connections for external conductors | ||
Number of main contacts (normally open contact) | ||
Rated breaking capacity at 220/230 V | ||
Screw size | M3.5, Terminal screw, Control circuit cables M5, Terminal screw, Main cables | |
Rated operational current (Ie) at AC-4, 400 V | ||
Short-circuit protection rating (type 2 coordination) at 690 V | ||
Assigned motor power at 575/600 V, 60 Hz, 3-phase | 15 HP | |
Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) | |
Rated operational power at AC-3, 440 V, 50 Hz | 10.5 kW | |
Terminal capacity (stranded) | 1 x 16 mm², Main cables | |
Rated breaking capacity at 500 V | ||
Rated operational power at AC-3, 415 V, 50 Hz | 10 kW | |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | |
Emitted interference | According to EN 60947-1 | |
Connection to SmartWire-DT | Yes In conjunction with DIL-SWD SmartWire DT contactor module | |
Static heat dissipation, non-current-dependent Pvs | ||
Rated control supply voltage (Us) at DC – max | 27 V | |
10.9.3 Impulse withstand voltage | ||
Utilization category | AC-3: Normal AC induction motors: starting, switch off during running AC-4: Normal AC induction motors: starting, plugging, reversing, inching AC-1: Non-inductive or slightly inductive loads, resistance furnaces | |
Rated operational current (Ie) at AC-3, 440 V | ||
10.5 Protection against electric shock | ||
Safe isolation | 440 V AC, Between coil and contacts, According to EN 61140 440 V AC, Between the contacts, According to EN 61140 | |
Operating voltage at AC, 50 Hz – min | ||
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | |
10.9.4 Testing of enclosures made of insulating material | ||
Heat dissipation per pole, current-dependent Pvid | 0.7 W | |
Actuating voltage | RDC 24: 24 – 27 V DC | |
Switching time (DC operated, make contacts, opening delay) – max | 30 ms | |
Switching capacity (auxiliary contacts, general use) | 10 A, 600 V AC, (UL/CSA) 1 A, 250 V DC, (UL/CSA) | |
Switching time (DC operated, make contacts, closing delay) – max | 47 ms | |
Rated operational current (Ie) at AC-4, 660 V, 690 V | 8 A | |
Equipment heat dissipation, current-dependent Pvid | 2.1 W | |
Assigned motor power at 200/208 V, 60 Hz, 3-phase | ||
Pick-up voltage | 24 – 27 V DC (RDC 24) 0.7 – 1.2 V DC x Uc | |
Suitable for | Also motors with efficiency class IE3 | |
Conventional thermal current ith at 40°C (3-pole, open) | ||
Terminal capacity (solid) | 1 x (0.75 – 16) mm², Main cables 2 x (0.75 – 2.5) mm², Control circuit cables 1 x (0.75 – 4) mm², Control circuit cables 2 x (0.75 – 10) mm², Main cables | |
Number of auxiliary contacts (normally closed contacts) | ||
Interference immunity | ||
10.2.3.2 Verification of resistance of insulating materials to normal heat | ||
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | ||
Lifespan, mechanical | 10,000,000 Operations (DC operated) | |
Short-circuit protection rating (type 1 coordination) at 690 V | 50 A gG/gL | |
Rated making capacity up to 690 V (cos phi to IEC/EN 60947) | 238 A | |
Rated operational power at AC-4, 240 V, 50 Hz | 3 kW | |
Rated operational power at AC-4, 500 V, 50 Hz | 6 kW | |
Rated operational current (Ie) at DC-1, 60 V | ||
Rated operational power at AC-4, 220/230 V, 50 Hz | 2.5 kW | |
Rated operational voltage (Ue) at AC – max | ||
Rated control supply voltage (Us) at AC, 60 Hz – min | ||
10.7 Internal electrical circuits and connections | ||
Power consumption (pick-up) at DC | 12 W | |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | |
Switching capacity (main contacts, general use) | 40 A, Maximum motor rating (UL/CSA) | |
Conventional thermal current ith at 50°C (3-pole, open) | 38 A | |
Rated operational current (Ie) at AC-3, 500 V | ||
Assigned motor power at 230/240 V, 60 Hz, 1-phase | 3 HP | |
Screwdriver size | 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver 2, Terminal screw, Pozidriv screwdriver | |
Duty factor | 100 % | |
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | ||
Conventional thermal current ith of main contacts (1-pole, open) | 88 A | |
Rated control supply voltage (Us) at AC, 60 Hz – max | ||
Arcing time | 10 ms | |
Rated operational power at AC-4, 415 V, 50 Hz | 5 kW | |
Switching capacity (auxiliary contacts, pilot duty) | A600, AC operated (UL/CSA) P300, DC operated (UL/CSA) | |
Rated insulation voltage (Ui) | ||
Altitude | Max. 2000 m | |
Catalogs | Product Range Catalog Switching and protecting motors | |
SmartWire-DT Catalog | ||
Product overview for machinery | ||
Switching and protecting motors – catalog | ||
Certification reports | 0000SPC-571 | |
Characteristic curve | eaton-contactors-component-dilm-characteristic-curve-003.eps | |
2100DIA-7 | ||
210U038 | ||
2100DIA-8 | ||
eaton-contactors-switch-dilm-characteristic-curve.eps | ||
eaton-contactors-short-time-loading-dilm-characteristic-curve.eps | ||
eaton-contactors-switch-dilm-characteristic-curve-002.eps | ||
210U039 | ||
Drawings | eaton-contactors-mounting-dilm-dimensions-002.eps | |
eaton-contactors-contact-dilm-dimensions-002.eps | ||
210N018 | ||
eaton-contactors-dilm-dimensions.eps | ||
210X202 | ||
eaton-contactors-mounting-dilm-dimensions.eps | ||
210N017 | ||
210T014 | ||
eaton-contactors-dilm-3d-drawing-009.eps | ||
210I192 | ||
eaton-general-ie-ready-dilm-contactor-standards.eps | ||
eCAD model | DA-CE-ETN.DILM17-10(RDC24) | |
Installation instructions | IL03407014Z2018_07 | |
IL03407014Z | ||
mCAD model | DA-CS-dil_m17_38 | |
DA-CD-dil_m17_38 | ||
PEP Eco-passport | EATO-00026-V01.01-EN | |
Specifications and datasheets | Eaton Specification Sheet – 277018 | |
System overview | 210O154 | |
eaton-contactors-dilm-contactor-system-overview.eps | ||
Wiring diagrams | eaton-contactors-contact-dilm-wiring-diagram.eps | |
210S026 | ||
Date | Thu Jul 20 2023 |