DC ACB WZ3

SKU WZ3

CategoryDC ACB

Description

  1. High breaking capacity
    It has a number of invention patents for the design of circuit breaker arc-extinguishing chamber andcontact system. Using the principles of narrow slit, air blowing, and magnetic blowing arc extinguishing,optimizing the shape of the arc extinguishing grid and the layout of the arc extinguishing grid, increasingthe driving force for the arc, reducing the resistance of entering the arc extinguishing chamber, andimproving the breaking capacity of the product,and realize reliable arc extinguishing lower than DC1500V.The time for the controller to collect signals and issue commands is optimized, and when a large faultcurrent occurs, the total breaking time can be greatly shortened.
  2. Long lifespan
    Made of high-strength DMC material, which has extremely high impact strength and insulation properties.The design of the arc contact structure improves the electrical life of the product; the contact system andoperating mechanism are greatly optimized, the strength of the metal structure is higher, and thecompensation of the contact pressure is realized, which improves the reliability of the product and short-term tolerance.
  3. Small size
    The phase spacing is the smallest among the same frame, and the shunt is built-in, which is conducive toreducing the size of the complete cabinet and making the product more beautiful.critical current
    The first non-polar frame circuit breaker at home and abroad that meets the critical DC load, realizesreliable arc extinguishing in the full current range, and can meet the photovoltaic PV2 level isolationrequirements.
  4. Various safety protection devices
    It has protective devices such as drawer-type circuit breaker door interlock, drawer-type three-positionlocking and unlocking device, key lock at off position, terminal shield, closing ready device, etc.
WZ3-2500 GYW3-4000
Number of poles in series (P) 2/3/4 3/4
Rated current In(A ) 800/1000/1250/1600/2000/2500 1600/2000/2500/3200/3600/4000
Rated working voltage Ue(V) DC500V/750V(2P/3P)DC1000V/1500V(4P) DC500V/750V(3P)

DC1000V/1500V(4P)

Breaking type / S H
Rated ultimate short-circuit
breaking capacity lcu(kA)
DC500V  2P  50
 3P  65 80 120
750V DC  2P  40 / /
 3P  55 65 80
DC1000V

DC1500V

 4P  50 55 75
 4P  40 50 60
Rated operating short-circuit breaking capacity lcs(kA) 100%lcu 100%lcu
Rated short-circuit making capacity lcm(kA) 100%lcu 100%Icu
Rated short-time withstand current Icw(kA)/1s 100%lcu 100%lcu
cont rol ler NWK20Z controller / /
NWK22Z controller / /
installation method Fixed / /
Drawer type / /