EATON MOELLER® SERIES DILM CONTACTOR 277898

Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 30 kW, 24 V 50/60 Hz, AC operation, Screw terminals

Description

General specifications Product Name Eaton Moeller® series DILM contactor
Catalog Number 277898
Model Code DILM65(24V50/60HZ)
EAN 4015082778989
Product Length/Depth 132.1 mm
Product Height 115 mm
Product Width 55 mm
Product Weight 0.872 kg
Certifications CE CSA File No.: 012528 UL UL 60947-4-1 IEC/EN 60947 VDE 0660 CSA-C22.2 No. 60947-4-1-14 UL Category Control No.: NLDX CSA IEC/EN 60947-4-1 UL File No.: E29096 CSA Class No.: 2411-03, 3211-04
Catalog Notes Contacts according to EN 50012
Product specifications Terminal capacity (flexible with ferrule) 1 x (0.75 – 35) mm², Main cables 2 x (0.75 – 25) mm², Main cables 1 x (0.75 – 2.5) mm², Control circuit cables 2 x (0.75 – 2.5) mm², Control circuit cables
Rated operational current for specified heat dissipation (In) 65 A
10.11 Short-circuit rating Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Rated operational power at AC-3, 380/400 V, 50 Hz 30 kW
Conventional thermal current ith (3-pole, enclosed) 72 A
Rated operational power at AC-4, 380/400 V, 50 Hz 12 kW
Rated operational current (Ie) at AC-4, 440 V 25 A
Terminal capacity (copper band) 2 x (6 x 9 x 0.8) mm (Number of segments x width x thickness), Main cables
Rated control supply voltage (Us) at AC, 50 Hz – min 24 V
Conventional thermal current ith at 60°C (3-pole, open) 80 A
10.4 Clearances and creepage distances Meets the product standard’s requirements.
Number of contacts (normally closed) as main contact 0
Short-circuit current rating (high fault at 480 V) 30/100 kA, Fuse, SCCR (UL/CSA) 100 A, max. CB, SCCR (UL/CSA) 250/150 A, Class J, max. Fuse, SCCR (UL/CSA) 65 kA, CB, SCCR (UL/CSA)
Conventional thermal current ith at 55°C (3-pole, open) 83 A
Rated operational power (NEMA) 37 kW
10.2.3.1 Verification of thermal stability of enclosures
Ambient storage temperature – min 40 °C
Rated breaking capacity at 380/400 V 650 A
Short-circuit current rating (basic rating) 250 A, max. CB, SCCR (UL/CSA) 10 kA, SCCR (UL/CSA) 250 A, max. Fuse, SCCR (UL/CSA)
Rated control supply voltage (Us) at AC, 50 Hz – max
Rated breaking capacity at 660/690 V 370 A
Rated operational current (Ie) at DC-1, 220 V
Special purpose rating of elevator control 32.2 A, 200 V 60 Hz 3-ph, (UL/CSA) 10 HP, 200 V 60 Hz 3-ph, (UL/CSA) 41 A, 600 V 60 Hz 3-ph, (UL/CSA) 30 HP, 480 V 60 Hz 3-ph, (UL/CSA) 40 A, 480 V 60 Hz 3-ph, (UL/CSA) 40 HP, 600 V 60 Hz 3-ph, (UL/CSA) 15 HP, 240 V 60 Hz 3-ph, (UL/CSA) 42 A, 240 V 60 Hz 3-ph, (UL/CSA)
Ambient operating temperature – max 60 °C
Assigned motor power at 115/120 V, 60 Hz, 1-phase 5 HP
Rated operational power at AC-4, 440 V, 50 Hz 14 kW
Electrical connection type of main circuit Screw connection
Number Of Poles Three-pole
Ambient operating temperature – min -25 °C
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
10.3 Degree of protection of assemblies
Application Contactors for Motors
Operating frequency 5000 mechanical Operations/h (AC operated)
Voltage type AC
Short-circuit protection rating (type 1 coordination) at 400 V 250 A gG/gL
Product category Contactors
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
Rated operational power at AC-3, 690 V, 50 Hz 35 kW
Power consumption, pick-up, 50 Hz 154 VA, Dual-frequency coil in a cold state and 1.0 x Us 168 VA, Dual-frequency coil in a cold state and 1.0 x Us
Heat dissipation capacity Pdiss 0 W
Assigned motor power at 460/480 V, 60 Hz, 3-phase 50 HP
Special purpose rating of tungsten incandescent lamps 88 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) 88 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Switching time (AC operated, make contacts, opening delay) – min 8 ms
Rated operational current (Ie) at AC-4, 500 V
Rated operational power at AC-3, 240 V, 50 Hz 22 kW
Terminal capacity (solid/stranded AWG) 18 – 14, Control circuit cables Single 14 – 1, double 14 – 2, Main cables
10.9.2 Power-frequency electric strength Is the panel builder’s responsibility.
Degree of protection IP00
Overvoltage category III
Switching time (AC operated, make contacts, opening delay) – max 13 ms
Ambient storage temperature – max 80 °C
Pollution degree 3
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V 98 A
Power consumption, pick-up, 60 Hz 168 VA, Dual-frequency coil in a cold state and 1.0 x Us 154 VA, Dual-frequency coil in a cold state and 1.0 x Us
Switching time (AC operated, make contacts, closing delay) – max 18 ms
Rated impulse withstand voltage (Uimp) 8000 V AC
Connection Screw terminals
Tightening torque 1.2 Nm, Screw terminals, Control circuit cables 3.3 Nm, Screw terminals, Main cables
Rated operational power at AC-4, 660/690 V, 50 Hz 17 kW
Frame size FS3
Conventional thermal current ith (1-pole, enclosed) 180 A
Rated operational current (Ie) at AC-3, 660 V, 690 V 37 A
10.2.2 Corrosion resistance
10.2.4 Resistance to ultra-violet (UV) radiation
10.2.7 Inscriptions
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
Switching time (AC operated, make contacts, closing delay) – min 12 ms
Short-circuit protection rating (type 2 coordination) at 400 V 125 A gG/gL
Special purpose rating of ballast electrical discharge lamps 88 A (600V 60Hz 3phase, 347V 60Hz 1phase) 88 A (480V 60Hz 3phase, 277V 60Hz 1phase)
Number of auxiliary contacts (normally open contacts)
Special purpose rating of definite purpose rating 390 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 65 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Rated operational power at AC-3, 500 V, 50 Hz 47 kW
Shock resistance 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Rated operational current (Ie) at DC-1, 110 V
Assigned motor power at 230/240 V, 60 Hz, 3-phase 25 HP
Drop-out voltage AC operated: 0.6 – 0.3 x UC, AC operated
Power consumption, sealing, 60 Hz 22 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 4.1 W, Dual-frequency coil in a cold state and 1.0 x Us 14 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Resistance per pole 1.9 mΩ
Ambient operating temperature (enclosed) – min 25 °C
Stripping length (control circuit cable) 10 mm
10.12 Electromagnetic compatibility
10.2.5 Lifting
Stripping length (main cable) 14 mm
Ambient operating temperature (enclosed) – max
Special purpose rating of resistance air heating
Rated control supply voltage (Us) at DC – min 0 V
Short-circuit current rating (high fault at 600 V) 30 kA, CB, SCCR (UL/CSA) 250/150 A, Class J, max. Fuse, SCCR (UL/CSA) 30/100 kA, Fuse, SCCR (UL/CSA) 250 A, max. CB, SCCR (UL/CSA)
10.8 Connections for external conductors
Number of main contacts (normally open contact)
Rated breaking capacity at 220/230 V
Screw size M6, Terminal screw, Main cables M3.5, Terminal screw, Control circuit cables
Rated operational current (Ie) at AC-4, 400 V
Short-circuit protection rating (type 2 coordination) at 690 V 80 A gG/gL
Assigned motor power at 575/600 V, 60 Hz, 3-phase 60 HP
Protection Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Power consumption, sealing, 50 Hz 4.1 W, Dual-frequency coil in a cold state and 1.0 x Us
Rated operational power at AC-3, 440 V, 50 Hz 41 kW
Terminal capacity (stranded) 2 x (16 – 35) mm², Main cables 1 x (16 – 50) mm², Main cables
Rated breaking capacity at 500 V
Rated operational power at AC-3, 415 V, 50 Hz 39 kW
Climatic proofing Damp heat, cyclic, to IEC 60068-2-30 Damp heat, constant, to IEC 60068-2-78
Emitted interference According to EN 60947-1
Connection to SmartWire-DT No
Static heat dissipation, non-current-dependent Pvs 4.1 W
Rated control supply voltage (Us) at DC – max
10.9.3 Impulse withstand voltage
Utilization category AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-4: Normal AC induction motors: starting, plugging, reversing, inching AC-3: Normal AC induction motors: starting, switch off during running
Rated operational current (Ie) at AC-3, 440 V
10.5 Protection against electric shock
Safe isolation 440 V AC, Between the contacts, According to EN 61140 440 V AC, Between coil and contacts, According to EN 61140
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.9.4 Testing of enclosures made of insulating material
Heat dissipation per pole, current-dependent Pvid 5.7 W
Actuating voltage 24 V 50/60 Hz
Rated operational current (Ie) at AC-4, 660 V, 690 V 20 A
Equipment heat dissipation, current-dependent Pvid 17.1 W
Assigned motor power at 200/208 V, 60 Hz, 3-phase 20 HP
Pick-up voltage 0.8 – 1.1 V AC x Uc
Suitable for Also motors with efficiency class IE3
Conventional thermal current ith at 40°C (3-pole, open)
Terminal capacity (solid) 2 x (0.75 – 2.5) mm², Control circuit cables 2 x (0.75 – 16) mm², Main cables 1 x (0.75 – 16) mm², Main cables 1 x (0.75 – 4) mm², Control circuit cables
Number of auxiliary contacts (normally closed contacts)
Interference immunity
10.2.3.2 Verification of resistance of insulating materials to normal heat
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Lifespan, mechanical 10,000,000 Operations (AC operated) 7,000,000 Operations (Coil 50/60 Hz)
Short-circuit protection rating (type 1 coordination) at 690 V 100 A gG/gL
Rated making capacity up to 690 V (cos phi to IEC/EN 60947) 910 A
Rated operational power at AC-4, 240 V, 50 Hz 7.5 kW
Rated operational power at AC-4, 500 V, 50 Hz 16 kW
Rated operational current (Ie) at DC-1, 60 V
Rated operational power at AC-4, 220/230 V, 50 Hz 7 kW
Rated operational voltage (Ue) at AC – max 690 V
Rated control supply voltage (Us) at AC, 60 Hz – min
10.7 Internal electrical circuits and connections
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Switching capacity (main contacts, general use) 88 A, Maximum motor rating (UL/CSA)
Conventional thermal current ith at 50°C (3-pole, open) 88 A
Rated operational current (Ie) at AC-3, 500 V
Assigned motor power at 230/240 V, 60 Hz, 1-phase 15 HP
Screwdriver size 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver 2, Terminal screw, Pozidriv screwdriver
Duty factor 100 %
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
Conventional thermal current ith of main contacts (1-pole, open) 200 A
Rated control supply voltage (Us) at AC, 60 Hz – max
Arcing time 10 ms
Rated operational power at AC-4, 415 V, 50 Hz 13 kW
Rated insulation voltage (Ui)
Altitude Max. 2000 m
Catalogs  Product Range Catalog Switching and protecting motors
 Switching and protecting motors – catalog
 SmartWire-DT Catalog
 Product overview for machinery
Certification reports  DA-DC-00004070.pdf
 DA-DC-00004229.pdf
 0000SPC-571
Characteristic curve  210U038
 2100DIA-7
 eaton-contactors-switch-dilm-characteristic-curve.eps
 eaton-contactors-component-dilm-characteristic-curve-003.eps
 eaton-contactors-switch-dilm-characteristic-curve-002.eps
 2100DIA-8
Drawings  210X214
 eaton-contactors-dilm-dimensions-012.eps
 eaton-contactors-mounting-dilm-dimensions.eps
 210N017
 eaton-contactors-dilm-dimensions-002.eps
 210T015
 210N018
 eaton-contactors-mounting-dilm-dimensions-002.eps
 eaton-general-ie-ready-dilm-contactor-standards.eps
 210I194
 2100DRW-96
 eaton-contactors-dilm-3d-drawing-011.eps
 eaton-contactors-mounting-dilm-3d-drawing.eps
eCAD model  DA-CE-ETN.DILM65(24V50_60HZ)
Installation instructions  IL03407033Z
mCAD model  DA-CS-dil_m40_72
 DA-CD-dil_m40_72
PEP Eco-passport  EATO-00027-V01.01-EN
Specifications and datasheets  Eaton Specification Sheet – 277898
System overview  210O154
 eaton-contactors-dilm-contactor-system-overview.eps
Wiring diagrams  eaton-contactors-contact-dilm-wiring-diagram-003.eps
 210S045
Date Thu Jul 20 2023