Eaton Moeller® series DILA Auxiliary contact module, 4 pole, Ith= 16 A, 2 N/O, 2 NC, Front fixing, Screw terminals, DILA, DILM7 – DILM38
Description
General specifications | Product Name | Eaton Moeller® series DILA Accessory Auxiliary contact module |
Catalog Number | 276426 | |
Model Code | DILA-XHI22 | |
UPC | 782116354597 | |
EAN | 4015082764265 | |
Product Length/Depth | 45 mm | |
Product Height | 38 mm | |
Product Width | 36 mm | |
Product Weight | 0.049 kg | |
Certifications | IEC/EN 60947-4-1 CSA-C22.2 No. 14-05 UL Category Control No.: NKCR CSA UL 508 VDE 0660 CSA Class No.: 3211-03 CE IEC/EN 60947 CSA File No.: 012528 UL UL File No.: E29184 | |
Product specifications | Rated operational current for specified heat dissipation (In) | 4 A |
Terminal capacity (flexible with ferrule) | 1 x (0.75 – 2.5) mm², Screw terminals 2 x (0.75 – 2.5) mm², Screw terminals | |
10.11 Short-circuit rating | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | |
Ambient operating temperature (enclosed) – min | 25 °C | |
Lamp holder | None | |
10.4 Clearances and creepage distances | Meets the product standard’s requirements. | |
10.12 Electromagnetic compatibility | ||
Mounting method | Front fastening | |
10.2.5 Lifting | Does not apply, since the entire switchgear needs to be evaluated. | |
Ambient operating temperature (enclosed) – max | 40 °C | |
10.2.3.1 Verification of thermal stability of enclosures | ||
Ambient storage temperature – min | ||
Fitted with: | Interlocked opposing contacts Switching elements according to EN 50005 | |
10.8 Connections for external conductors | Is the panel builder’s responsibility. | |
Screw size | M3.5, Terminal screw | |
Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) | |
Ambient operating temperature – max | 60 °C | |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | |
Code number | 62E in combination with DILA(C)-40 44 in combination with DILA(C)-22 53 in combination with DILA(C)-31 | |
Features | Interlocked opposing contacts within an auxiliary contact module (according to IEC 60947-5-1 Annex L) | |
Lifespan, electrical | 1,300,000 Operations (at 230 V, AC-15, 3 A) | |
Static heat dissipation, non-current-dependent Pvs | 0 W | |
Rated operational current (Ie) at AC-15, 500 V | 1.5 A | |
10.9.3 Impulse withstand voltage | ||
Number of poles | Four-pole | |
Ambient operating temperature – min | -25 °C | |
10.6 Incorporation of switching devices and components | ||
10.5 Protection against electric shock | ||
Safe isolation | 400 V AC, Between auxiliary contacts, According to EN 61140 400 V AC, Between coil and auxiliary contacts, According to EN 61140 | |
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V | ||
Electric connection type | Screw connection | |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | |
10.2.6 Mechanical impact | ||
10.9.4 Testing of enclosures made of insulating material | ||
Number of contacts (normally closed contacts) | 2 | |
10.3 Degree of protection of assemblies | ||
Heat dissipation per pole, current-dependent Pvid | 0.16 W | |
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V | ||
Operating frequency | 9000 Operations/h | |
Switching capacity (auxiliary contacts, general use) | 1 A, 250 V DC, (UL/CSA) 10 A, 600 V AC, (UL/CSA) | |
Number of switches (fault signal) | 0 | |
Equipment heat dissipation, current-dependent Pvid | ||
Heat dissipation capacity Pdiss | ||
Rated operational current (Ie) at DC-13, 60 V | 1 A | |
Conventional thermal current ith at 60°C (3-pole, open) | 16 A | |
Rated operational current (Ie) | 10 A at 60 V, DC L/R ≤ 15 ms (with 2 contacts in series) 6 A at 60 V, DC L/R ≤ 15 ms (with 1 contact in series) 1 A at 220 V, DC L/R ≤ 15 ms (with 1 contact in series) 0.5 A at 110 V, DC L/R ≤ 50 ms (with 3 contacts in series) 1 A at 60 V, DC L/R ≤ 50 ms (with 3 contacts in series) 5 A at 220 V, DC L/R ≤ 15 ms (with 3 contacts in series) 2.5 A at 24 V, DC L/R ≤ 50 ms (with 3 contacts in series) 10 A at 24 V, DC L/R ≤ 15 ms (with 1 contact in series) 0.25 A at 220 V, DC L/R ≤ 50 ms (with 3 contacts in series) 3 A at 110 V, DC L/R ≤ 15 ms (with 1 contact in series) 6 A at 110 V, DC L/R ≤ 15 ms (with 3 contacts in series) | |
Short-circuit protection rating without welding | 10 A gG/gL, 500 V, Max. Fuse, Contacts | |
Terminal capacity (solid) | 2 x (0.75 – 2.5) mm², Screw terminals 1 x (0.75 – 2.5) mm², Screw terminals | |
10.2.3.2 Verification of resistance of insulating materials to normal heat | ||
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | ||
Lifespan, mechanical | 10,000,000 Operations (DC operated) 10,000,000 Operations (AC operated) | |
Rated operational current (Ie) at DC-13, 220 V, 230 V | 0.25 A | |
Terminal capacity (solid/stranded AWG) | 18 – 14, Screw terminals | |
10.9.2 Power-frequency electric strength | ||
Control circuit reliability | < 2 λ, < 1 failure at 100,000,000 Operations (at Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA) | |
Overvoltage category | III | |
Degree of protection | IP20 | |
Ambient storage temperature – max | 80 °C | |
Rated operational voltage (Ue) at AC – max | 500 V | |
Pollution degree | 3 | |
10.7 Internal electrical circuits and connections | ||
Rated impulse withstand voltage (Uimp) | 6000 V AC | |
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | |
Functions | For standard applications | |
Tightening torque | 1.2 Nm, Screw terminals | |
Screwdriver size | 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver 2, Terminal screw, Pozidriv screwdriver | |
Type | Front mounting auxiliary contact | |
10.2.2 Corrosion resistance | ||
10.2.4 Resistance to ultra-violet (UV) radiation | ||
10.2.7 Inscriptions | ||
Number of contacts (normally open contacts) | ||
Short-circuit protection rating | Max. 10 A gG/gL, Fuse, Without welding, Auxiliary contacts | |
Model | Top mounting | |
Rated operational current (Ie) at DC-13, 110 V | 0.5 A | |
Number of contacts (change-over contacts) | ||
Shock resistance | 5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms | |
Switching capacity (auxiliary contacts, pilot duty) | P300, DC operated (UL/CSA) A600, AC operated (UL/CSA) | |
Rated insulation voltage (Ui) | 690 V | |
Rated operational current (Ie) at DC-13, 24 V | 2.5 A | |
Catalogs | Product overview for machinery | |
Switching and protecting motors – catalog | ||
Product Range Catalog Switching and protecting motors | ||
Certification reports | DA-DC-00004245.pdf | |
DA-DC-00004246.pdf | ||
DA-DC-00004110.pdf | ||
DA-DC-00004109.pdf | ||
Drawings | eaton-contactors-module-dilm-dimensions.eps | |
210N018 | ||
210T013 | ||
eaton-contactors-mounting-dilm-dimensions-002.eps | ||
eaton-contactors-frame-dilm-dimensions.eps | ||
eaton-contactors-mounting-dilm-dimensions.eps | ||
2110DIM-1 | ||
210N017 | ||
eaton-contactors-contact-dilm-accessory-3d-drawing-008.eps | ||
210I105 | ||
eCAD model | ETN.DILA-XHI22 | |
Installation instructions | IL03407013Z | |
mCAD model | dil_a_xhi_4.stp | |
dil_a_xhi_4 | ||
Specifications and datasheets | Eaton Specification Sheet – 276426 | |
Wiring diagrams | 2100SWI-115 | |
210S008 | ||
eaton-contactors-contact-dila-accessory-wiring-diagram-004.eps | ||
Date | Thu Jul 20 2023 |