EATON MOELLER® SERIES DILM CONTACTOR 276690

Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 4 kW, 1 N/O, 230 V 50 Hz, 240 V 60 Hz, AC operation, Screw terminals DILM9-10(230V50HZ,240V60HZ)

Description

General specifications Product Name Eaton Moeller® series DILM contactor
Catalog Number 276690
Model Code DILM9-10(230V50HZ,240V60HZ)
EAN 4015082766900
Product Length/Depth 75 mm
Product Height 68 mm
Product Width 45 mm
Product Weight 0.24 kg
Certifications IEC/EN 60947 UL File No.: E29096 UL IEC/EN 60947-4-1 UL 60947-4-1 UL Category Control No.: NLDX CSA CE CSA-C22.2 No. 60947-4-1-14 VDE 0660 CSA Class No.: 2411-03, 3211-04 CSA File No.: 012528
Catalog Notes Contacts according to EN 50012
Product specifications Terminal capacity (flexible with ferrule) 1 x (0.75 – 2.5) mm² 2 x (0.75 – 2,5) mm² 2 x (0.75 – 2.5) mm²
Rated operational current for specified heat dissipation (In) 9 A
10.11 Short-circuit rating Is the panel builder’s responsibility. The specifications for the switchgear must be observed.
Rated operational power at AC-3, 380/400 V, 50 Hz 4 kW
Conventional thermal current ith (3-pole, enclosed) 18 A
Rated operational power at AC-4, 380/400 V, 50 Hz 2.5 kW
Rated operational current (Ie) at AC-4, 440 V 6 A
Rated control supply voltage (Us) at AC, 50 Hz – min 230 V
Conventional thermal current ith at 60°C (3-pole, open) 20 A
10.4 Clearances and creepage distances Meets the product standard’s requirements.
Number of contacts (normally closed) as main contact 0
Short-circuit current rating (high fault at 480 V) 30/100 kA, Fuse, SCCR (UL/CSA) 65 kA, CB, SCCR (UL/CSA) 25 A, Class RK5/ 20 A Class J, max. Fuse, SCCR (UL/CSA) 16 A, max. CB, SCCR (UL/CSA)
Conventional thermal current ith at 55°C (3-pole, open) 21 A
Rated operational power (NEMA) 3.7 kW
10.2.3.1 Verification of thermal stability of enclosures
Ambient storage temperature – min 40 °C
Rated breaking capacity at 380/400 V 90 A
Short-circuit current rating (basic rating) 60 A, max. CB, SCCR (UL/CSA) 45 A, max. Fuse, SCCR (UL/CSA) 5 kA, SCCR (UL/CSA)
Rated control supply voltage (Us) at AC, 50 Hz – max
Rated breaking capacity at 660/690 V 50 A
Rated operational current (Ie) at DC-1, 220 V 15 A
Special purpose rating of elevator control 2 HP, 240 V 60 Hz 3-ph, (UL/CSA) 7.8 A, 200 V 60 Hz 3-ph, (UL/CSA) 3 HP, 480 V 60 Hz 3-ph, (UL/CSA) 6.8 A, 240 V 60 Hz 3-ph, (UL/CSA) 6.1 A, 600 V 60 Hz 3-ph, (UL/CSA) 2 HP, 200 V 60 Hz 3-ph, (UL/CSA) 5 HP, 600 V 60 Hz 3-ph, (UL/CSA) 4.8 A, 480 V 60 Hz 3-ph, (UL/CSA)
Ambient operating temperature – max 60 °C
Assigned motor power at 115/120 V, 60 Hz, 1-phase 0.5 HP
Rated operational power at AC-4, 440 V, 50 Hz 3 kW
Electrical connection type of main circuit Screw connection
Number Of Poles Three-pole
Ambient operating temperature – min -25 °C
10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
10.3 Degree of protection of assemblies
Application Contactors for Motors
Operating frequency 9000 mechanical Operations/h (AC operated)
Voltage type AC
Short-circuit protection rating (type 1 coordination) at 400 V 35 A gG/gL
Product category Contactors
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
Rated operational power at AC-3, 690 V, 50 Hz 4.5 kW
Power consumption, pick-up, 50 Hz 24 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Heat dissipation capacity Pdiss 0 W
Assigned motor power at 460/480 V, 60 Hz, 3-phase 5 HP
Special purpose rating of tungsten incandescent lamps 14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) 14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Switching time (AC operated, make contacts, opening delay) – min 9 ms
Rated operational current (Ie) at AC-4, 500 V 5 A
Rated operational power at AC-3, 240 V, 50 Hz
Operating voltage at AC, 60 Hz – max 690 V
Terminal capacity (solid/stranded AWG) Single 18 – 10, double 18 – 14
10.9.2 Power-frequency electric strength Is the panel builder’s responsibility.
Degree of protection IP20
Overvoltage category III
Switching time (AC operated, make contacts, opening delay) – max 18 ms
Ambient storage temperature – max 80 °C
Pollution degree 3
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V 22 A
Power consumption, pick-up, 60 Hz 30 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Switching time (AC operated, make contacts, closing delay) – max 21 ms
Rated impulse withstand voltage (Uimp) 8000 V AC
Connection Screw terminals
Operating voltage at AC, 60 Hz – min 24 V
Tightening torque 1.2 Nm, Screw terminals
Rated operational power at AC-4, 660/690 V, 50 Hz 3.6 kW
Frame size FS1
Conventional thermal current ith (1-pole, enclosed) 45 A
Rated operational current (Ie) at AC-3, 660 V, 690 V
10.2.2 Corrosion resistance
10.2.4 Resistance to ultra-violet (UV) radiation
10.2.7 Inscriptions
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
Number of contacts (normally open contacts) 1
Switching time (AC operated, make contacts, closing delay) – min 15 ms
Short-circuit protection rating (type 2 coordination) at 400 V 20 A gG/gL
Special purpose rating of ballast electrical discharge lamps 18 A (480V 60Hz 3phase, 277V 60Hz 1phase) 18 A (600V 60Hz 3phase, 347V 60Hz 1phase)
Number of auxiliary contacts (normally open contacts)
Special purpose rating of definite purpose rating 54 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) 9 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Rated operational power at AC-3, 500 V, 50 Hz
Shock resistance 3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
Rated operational current (Ie) at DC-1, 110 V
Assigned motor power at 230/240 V, 60 Hz, 3-phase 3 HP
Drop-out voltage AC operated: 0.6 – 0.3 x UC, AC operated
Power consumption, sealing, 60 Hz 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 4.4 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Resistance per pole 2.5 mΩ
Ambient operating temperature (enclosed) – min 25 °C
Stripping length (control circuit cable) 10 mm
Operating voltage at AC, 50 Hz – max
10.12 Electromagnetic compatibility
Special purpose rating of refrigeration control (CSA only) 10 A, FLA 480 V 60 Hz 3phase; (CSA) 60 A, LRA 600 V 60 Hz 3phase; (CSA) 60 A, LRA 480 V 60 Hz 3phase; (CSA) 10 A, FLA 600 V 60 Hz 3phase; (CSA)
10.2.5 Lifting
Stripping length (main cable)
Ambient operating temperature (enclosed) – max
Special purpose rating of resistance air heating 18 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 18 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Rated control supply voltage (Us) at DC – min 0 V
Short-circuit current rating (high fault at 600 V) 30/100 kA, Fuse, SCCR (UL/CSA) 25 A, Class RK5/20 A, Class J, max. Fuse, SCCR (UL/CSA)
10.8 Connections for external conductors
Number of main contacts (normally open contact)
Rated breaking capacity at 220/230 V
Screw size M3.5, Terminal screw
Rated operational current (Ie) at AC-4, 400 V
Short-circuit protection rating (type 2 coordination) at 690 V 16 A gG/gL
Assigned motor power at 575/600 V, 60 Hz, 3-phase 7.5 HP
Protection Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Power consumption, sealing, 50 Hz 3.4 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz
Rated operational power at AC-3, 440 V, 50 Hz 5.5 kW
Rated breaking capacity at 500 V 70 A
Rated operational power at AC-3, 415 V, 50 Hz
Climatic proofing Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30
Emitted interference According to EN 60947-1
Connection to SmartWire-DT No
Static heat dissipation, non-current-dependent Pvs 1.4 W
Rated control supply voltage (Us) at DC – max
10.9.3 Impulse withstand voltage
Utilization category AC-3: Normal AC induction motors: starting, switch off during running AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Rated operational current (Ie) at AC-3, 440 V
10.5 Protection against electric shock
Safe isolation 400 V AC, Between the contacts, According to EN 61140 400 V AC, Between coil and contacts, According to EN 61140
Operating voltage at AC, 50 Hz – min
10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.9.4 Testing of enclosures made of insulating material
Heat dissipation per pole, current-dependent Pvid 0.2 W
Actuating voltage 230 V 50 Hz, 240 V 60 Hz
Switching capacity (auxiliary contacts, general use) 10 A, 600 V AC, (UL/CSA) 1 A, 250 V DC, (UL/CSA)
Rated operational current (Ie) at AC-4, 660 V, 690 V 4.5 A
Equipment heat dissipation, current-dependent Pvid
Assigned motor power at 200/208 V, 60 Hz, 3-phase
Pick-up voltage 0.8 – 1.1 V AC x Uc
Suitable for Also motors with efficiency class IE3
Conventional thermal current ith at 40°C (3-pole, open)
Terminal capacity (solid) 2 x (0.75 – 2.5) mm² 1 x (0.75 – 4) mm²
Number of auxiliary contacts (normally closed contacts)
Interference immunity
10.2.3.2 Verification of resistance of insulating materials to normal heat
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Lifespan, mechanical 10,000,000 Operations (AC operated)
Short-circuit protection rating (type 1 coordination) at 690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947) 112 A
Rated operational power at AC-4, 240 V, 50 Hz 1.6 kW
Rated operational power at AC-4, 500 V, 50 Hz 2.8 kW
Rated operational current (Ie) at DC-1, 60 V
Rated operational power at AC-4, 220/230 V, 50 Hz 1.5 kW
Rated operational voltage (Ue) at AC – max
Rated control supply voltage (Us) at AC, 60 Hz – min 240 V
10.7 Internal electrical circuits and connections
10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Switching capacity (main contacts, general use) 20 A, Maximum motor rating (UL/CSA)
Conventional thermal current ith at 50°C (3-pole, open)
Rated operational current (Ie) at AC-3, 500 V 7 A
Assigned motor power at 230/240 V, 60 Hz, 1-phase 1.5 HP
Screwdriver size 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver 2, Terminal screw, Pozidriv screwdriver
Duty factor 100 %
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
Conventional thermal current ith of main contacts (1-pole, open)
Rated control supply voltage (Us) at AC, 60 Hz – max
Arcing time 10 ms
Rated operational power at AC-4, 415 V, 50 Hz
Switching capacity (auxiliary contacts, pilot duty) A600, AC operated (UL/CSA) P300, DC operated (UL/CSA)
Rated insulation voltage (Ui)
Altitude Max. 2000 m
Catalogs  Product Range Catalog Switching and protecting motors
 Switching and protecting motors – catalog
 SmartWire-DT Catalog
Certification reports  0000SPC-571
Characteristic curve  210U038
 2100DIA-8
 2100DIA-7
 eaton-contactors-switch-dilm-characteristic-curve.eps
 eaton-contactors-component-dilm-characteristic-curve-003.eps
 eaton-contactors-switch-dilm-characteristic-curve-002.eps
Drawings  210T013
 eaton-contactors-module-dilm-dimensions-002.eps
 eaton-contactors-mounting-dilm-dimensions.eps
 eaton-contactors-mounting-dilm-dimensions-002.eps
 210N017
 210N018
 eaton-contactors-module-dilm-dimensions.eps
 2110DIM-1
 eaton-contactors-frame-dilm-dimensions.eps
 2110DIM-2
 eaton-general-ie-ready-dilm-contactor-standards.eps
 210I044
 eaton-contactors-dilm-3d-drawing-007.eps
eCAD model  DA-CE-ETN.DILM9-10(230V50HZ,240V60HZ)
Installation instructions  IL03407013Z2018_07
 IL03407013Z
mCAD model  DA-CS-dil_m7_15
 DA-CD-dil_m7_15
PEP Eco-passport  EATO-00023-V01.01-EN
Specifications and datasheets  Eaton Specification Sheet – 276690
System overview  eaton-contactors-dilm-contactor-system-overview.eps
 210O154
Wiring diagrams  210S026
 eaton-contactors-contact-dilm-wiring-diagram.eps
Date Thu Jul 20 2023