Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 18.5 kW, 230 V 50 Hz, 240 V 60 Hz, AC operation, Screw terminals DILM40(230V50HZ,240V60HZ)
Description
General specifications | Product Name | Eaton Moeller® series DILM contactor |
Catalog Number | 277766 | |
Model Code | DILM40(230V50HZ,240V60HZ) | |
EAN | 4015082777661 | |
Product Length/Depth | 132.1 mm | |
Product Height | 115 mm | |
Product Width | 55 mm | |
Product Weight | 0.872 kg | |
Warranty | Not Applicable | |
Compliances | CE Marked | |
Certifications | IEC 60947-4-1 CSA Std. C22.2 No. 14-05 UL 508 EN 60947-4-1 CSA Certified UL Listed VDE 0660 CSA IEC/EN 60947 UL 60947-4-1 CSA-C22.2 No. 60947-4-1-14 CE IEC/EN 60947-4-1 UL File No.: E29096 CSA File No.: 012528 UL UL Category Control No.: NLDX CSA Class No.: 2411-03, 3211-04 | |
Catalog Notes | Contacts according to EN 50012 | |
Product specifications | Terminal capacity (flexible with ferrule) | 2 x (0.75 – 2.5) mm², Control circuit cables 2 x (0.75 – 25) mm², Main cables 1 x (0.75 – 2.5) mm², Control circuit cables 1 x (0.75 – 35) mm², Main cables |
Rated operational current for specified heat dissipation (In) | 40 A | |
10.11 Short-circuit rating | Is the panel builder’s responsibility. The specifications for the switchgear must be observed. | |
Rated operational power at AC-3, 380/400 V, 50 Hz | 18.5 kW | |
Conventional thermal current ith (3-pole, enclosed) | 45 A | |
Rated operational power at AC-4, 380/400 V, 50 Hz | 9 kW | |
Rated operational current (Ie) at AC-4, 440 V | 18 A | |
Terminal capacity (copper band) | 2 x (6 x 9 x 0.8) mm (Number of segments x width x thickness), Main cables | |
Rated control supply voltage (Us) at AC, 50 Hz – min | 230 V | |
Conventional thermal current ith at 60°C (3-pole, open) | 50 A | |
10.4 Clearances and creepage distances | Meets the product standard’s requirements. | |
Number of contacts (normally closed) as main contact | 0 | |
Short-circuit current rating (high fault at 480 V) | 250/150 A, Class J, max. Fuse, SCCR (UL/CSA) 65 kA, CB, SCCR (UL/CSA) 100 A, max. CB, SCCR (UL/CSA) 30/100 kA, Fuse, SCCR (UL/CSA) | |
Conventional thermal current ith at 55°C (3-pole, open) | 55 A | |
Rated operational power (NEMA) | 22 kW | |
10.2.3.1 Verification of thermal stability of enclosures | ||
Ambient storage temperature – min | 40 °C | |
Rated breaking capacity at 380/400 V | 400 A | |
Short-circuit current rating (basic rating) | 10 kA, SCCR (UL/CSA) 250 A, max. CB, SCCR (UL/CSA) 250 A, max. Fuse, SCCR (UL/CSA) | |
Rated control supply voltage (Us) at AC, 50 Hz – max | ||
Rated breaking capacity at 660/690 V | 250 A | |
Operating temperature | -25° to 60°C | |
Rated operational current (Ie) at DC-1, 220 V | ||
Special purpose rating of elevator control | 10 HP, 240 V 60 Hz 3-ph, (UL/CSA) 25 HP, 480 V 60 Hz 3-ph, (UL/CSA) 7.5 HP, 200 V 60 Hz 3-ph, (UL/CSA) 28 A, 240 V 60 Hz 3-ph, (UL/CSA) 30 HP, 600 V 60 Hz 3-ph, (UL/CSA) 32 A, 600 V 60 Hz 3-ph, (UL/CSA) 34 A, 480 V 60 Hz 3-ph, (UL/CSA) 25.3 A, 200 V 60 Hz 3-ph, (UL/CSA) | |
Ambient operating temperature – max | 60 °C | |
Assigned motor power at 115/120 V, 60 Hz, 1-phase | 3 HP | |
Rated operational power at AC-4, 440 V, 50 Hz | 10 kW | |
Electrical connection type of main circuit | Screw connection | |
Number Of Poles | Three-pole | |
Ambient operating temperature – min | -25 °C | |
10.6 Incorporation of switching devices and components | Does not apply, since the entire switchgear needs to be evaluated. | |
10.2.6 Mechanical impact | ||
10.3 Degree of protection of assemblies | ||
Application | Contactors for Motors | |
Operating frequency | 5000 mechanical Operations/h (AC operated) | |
Voltage type | AC | |
Short-circuit protection rating (type 1 coordination) at 400 V | 125 A gG/gL | |
Product category | Contactors | |
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V | ||
Rated operational power at AC-3, 690 V, 50 Hz | 23 kW | |
Power consumption, pick-up, 50 Hz | 149 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz | |
Heat dissipation capacity Pdiss | 0 W | |
Assigned motor power at 460/480 V, 60 Hz, 3-phase | 30 HP | |
Special purpose rating of tungsten incandescent lamps | 74 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 74 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) | |
Switching time (AC operated, make contacts, opening delay) – min | 8 ms | |
Continuous ampere rating | 63 A | |
Rated operational current (Ie) at AC-4, 500 V | ||
Rated operational power at AC-3, 240 V, 50 Hz | 13.5 kW | |
Terminal capacity (solid/stranded AWG) | Single 14 – 1, double 14 – 2, Main cables 18 – 14, Control circuit cables | |
10.9.2 Power-frequency electric strength | Is the panel builder’s responsibility. | |
Degree of protection | IP00 | |
Overvoltage category | III | |
Switching time (AC operated, make contacts, opening delay) – max | 13 ms | |
Ambient storage temperature – max | 80 °C | |
Pollution degree | 3 | |
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 60 A | |
Power consumption, pick-up, 60 Hz | 178 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz | |
Switching time (AC operated, make contacts, closing delay) – max | 18 ms | |
Rated impulse withstand voltage (Uimp) | 8000 V AC | |
Connection | Screw terminals | |
Tightening torque | 1.2 Nm, Screw terminals, Control circuit cables 3.3 Nm, Screw terminals, Main cables | |
Rated operational power at AC-4, 660/690 V, 50 Hz | 12 kW | |
Frame size | FS3 | |
Conventional thermal current ith (1-pole, enclosed) | 112 A | |
Rated operational current (Ie) at AC-3, 660 V, 690 V | 25 A | |
Type | Full voltage non-reversing contactor | |
10.2.2 Corrosion resistance | ||
10.2.4 Resistance to ultra-violet (UV) radiation | ||
10.2.7 Inscriptions | ||
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | ||
Switching time (AC operated, make contacts, closing delay) – min | 12 ms | |
Short-circuit protection rating (type 2 coordination) at 400 V | 63 A gG/gL | |
Special purpose rating of ballast electrical discharge lamps | 79 A (480V 60Hz 3phase, 277V 60Hz 1phase) 79 A (600V 60Hz 3phase, 347V 60Hz 1phase) | |
Number of auxiliary contacts (normally open contacts) | ||
Rated operational power at AC-3, 500 V, 50 Hz | 28 kW | |
Shock resistance | 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms | |
Rated operational current (Ie) at DC-1, 110 V | ||
Assigned motor power at 230/240 V, 60 Hz, 3-phase | 15 HP | |
Drop-out voltage | AC operated: 0.6 – 0.3 x UC, AC operated | |
Power consumption, sealing, 60 Hz | 4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz 19 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz | |
Resistance per pole | 1.9 mΩ | |
Ambient operating temperature (enclosed) – min | 25 °C | |
Stripping length (control circuit cable) | 10 mm | |
10.12 Electromagnetic compatibility | ||
Amperage Rating | 170A | |
10.2.5 Lifting | ||
Stripping length (main cable) | 14 mm | |
Ambient operating temperature (enclosed) – max | ||
Special purpose rating of resistance air heating | 79 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA) 79 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) | |
Rated control supply voltage (Us) at DC – min | 0 V | |
Short-circuit current rating (high fault at 600 V) | 250 A, max. CB, SCCR (UL/CSA) 250/150 A, Class J, max. Fuse, SCCR (UL/CSA) 30 kA, CB, SCCR (UL/CSA) 30/100 kA, Fuse, SCCR (UL/CSA) | |
Frequency rating | 50-60 Hz | |
10.8 Connections for external conductors | ||
Number of main contacts (normally open contact) | ||
Rated breaking capacity at 220/230 V | ||
Screw size | M6, Terminal screw, Main cables M3.5, Terminal screw, Control circuit cables | |
Rated operational current (Ie) at AC-4, 400 V | ||
Terminals | Spring loaded terminals | |
Short-circuit protection rating (type 2 coordination) at 690 V | 50 A gG/gL | |
Assigned motor power at 575/600 V, 60 Hz, 3-phase | 40 HP | |
Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) | |
Power consumption, sealing, 50 Hz | 16 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz 4.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz | |
Rated operational power at AC-3, 440 V, 50 Hz | 25 kW | |
Terminal capacity (stranded) | 1 x (16 – 50) mm², Main cables 2 x (16 – 35) mm², Main cables | |
HP rating – max | 3, 7.5/ 10, 15, 30, 40 hp (1/3PH @120, 240/ 208, 240, 480, 600 V) | |
Rated breaking capacity at 500 V | ||
Rated operational power at AC-3, 415 V, 50 Hz | 24 kW | |
Climatic proofing | Damp heat, constant, to IEC 60068-2-78 Damp heat, cyclic, to IEC 60068-2-30 | |
Emitted interference | According to EN 60947-1 | |
Connection to SmartWire-DT | No | |
Static heat dissipation, non-current-dependent Pvs | 4.1 W | |
Rated control supply voltage (Us) at DC – max | ||
10.9.3 Impulse withstand voltage | ||
Utilization category | AC-3: Normal AC induction motors: starting, switch off during running AC-1: Non-inductive or slightly inductive loads, resistance furnaces AC-4: Normal AC induction motors: starting, plugging, reversing, inching | |
Coil voltage | 230-240 Vac, 50/60 Hz | |
Rated operational current (Ie) at AC-3, 440 V | ||
10.5 Protection against electric shock | ||
Safe isolation | 440 V AC, Between the contacts, According to EN 61140 440 V AC, Between coil and contacts, According to EN 61140 | |
10.13 Mechanical function | The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. | |
10.9.4 Testing of enclosures made of insulating material | ||
Heat dissipation per pole, current-dependent Pvid | 2.2 W | |
Actuating voltage | 230 V 50 Hz, 240 V 60 Hz | |
Operating temperature – min | ||
Rated operational current (Ie) at AC-4, 660 V, 690 V | 14 A | |
Equipment heat dissipation, current-dependent Pvid | 6.6 W | |
Assigned motor power at 200/208 V, 60 Hz, 3-phase | 10 HP | |
Pick-up voltage | 0.8 – 1.1 V AC x Uc | |
Suitable for | Also motors with efficiency class IE3 | |
Operation | Non-reversing | |
Conventional thermal current ith at 40°C (3-pole, open) | ||
Terminal capacity (solid) | 1 x (0.75 – 16) mm², Main cables 2 x (0.75 – 2.5) mm², Control circuit cables 2 x (0.75 – 16) mm², Main cables 1 x (0.75 – 4) mm², Control circuit cables | |
Number of auxiliary contacts (normally closed contacts) | ||
Interference immunity | ||
Power consumption | 18 kW | |
10.2.3.2 Verification of resistance of insulating materials to normal heat | ||
Operating temperature – max | ||
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects | ||
Lifespan, mechanical | 10,000,000 Operations (AC operated) | |
Short-circuit protection rating (type 1 coordination) at 690 V | 80 A gG/gL | |
Rated making capacity up to 690 V (cos phi to IEC/EN 60947) | 560 A | |
Rated operational power at AC-4, 240 V, 50 Hz | 5.5 kW | |
Rated operational power at AC-4, 500 V, 50 Hz | 11 kW | |
Voltage rating | 400 V | |
Rated operational current (Ie) at DC-1, 60 V | ||
Rated operational power at AC-4, 220/230 V, 50 Hz | 5 kW | |
Rated operational voltage (Ue) at AC – max | 690 V | |
Rated control supply voltage (Us) at AC, 60 Hz – min | 240 V | |
10.7 Internal electrical circuits and connections | ||
10.10 Temperature rise | The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. | |
Switching capacity (main contacts, general use) | 63 A, Maximum motor rating (UL/CSA) | |
Conventional thermal current ith at 50°C (3-pole, open) | 57 A | |
Rated operational current (Ie) at AC-3, 500 V | ||
Assigned motor power at 230/240 V, 60 Hz, 1-phase | 7.5 HP | |
Screwdriver size | 2, Terminal screw, Pozidriv screwdriver 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver | |
Duty factor | 100 % | |
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | ||
Conventional thermal current ith of main contacts (1-pole, open) | 125 A | |
Rated control supply voltage (Us) at AC, 60 Hz – max | ||
Arcing time | 10 ms | |
Rated operational power at AC-4, 415 V, 50 Hz | 9.5 kW | |
Rated insulation voltage (Ui) | ||
Altitude | Max. 2000 m | |
Catalogs | Product Range Catalog Switching and protecting motors | |
Switching and protecting motors – catalog | ||
Product overview for machinery | ||
SmartWire-DT Catalog | ||
Certification reports | DA-DC-00004070.pdf | |
DA-DC-00004229.pdf | ||
0000SPC-571 | ||
Characteristic curve | eaton-contactors-component-dilm-characteristic-curve-003.eps | |
eaton-contactors-switch-dilm-characteristic-curve.eps | ||
eaton-contactors-switch-dilm-characteristic-curve-002.eps | ||
210U038 | ||
2100DIA-7 | ||
2100DIA-8 | ||
Drawings | 210N018 | |
eaton-contactors-mounting-dilm-dimensions.eps | ||
eaton-contactors-dilm-dimensions-002.eps | ||
210T015 | ||
eaton-contactors-dilm-dimensions-012.eps | ||
210X214 | ||
eaton-contactors-mounting-dilm-dimensions-002.eps | ||
210N017 | ||
eaton-contactors-mounting-dilm-3d-drawing.eps | ||
eaton-general-ie-ready-dilm-contactor-standards.eps | ||
eaton-contactors-dilm-3d-drawing-011.eps | ||
210I194 | ||
2100DRW-96 | ||
eCAD model | ETN.DILM40(230V50HZ,240V60HZ) | |
Installation instructions | IL03407033Z | |
mCAD model | DA-CD-dil_m40_72 | |
DA-CS-dil_m40_72 | ||
PEP Eco-passport | EATO-00027-V01.01-EN | |
Specifications and datasheets | Product Data Sheet – 277766 | |
Eaton Specification Sheet – 277766 | ||
System overview | eaton-contactors-dilm-contactor-system-overview.eps | |
210O154 | ||
Wiring diagrams | eaton-contactors-contact-dilm-wiring-diagram-003.eps | |
210S045 | ||
Date | Thu Jul 20 2023 |