The PGS-12~40.5 pole-mounted insulation load switch is designed to operate in power grids with rated voltages of 12~ 40.5kV. It can handle rated currents of 400A and 630A at 50/60Hz, being capable of opening and closing circuit, load, and overload currents. This switch can automatically isolate faulty distribution lines.
Description
Standard Conditions of Use
Key Features
Parameters ratings
No. | Name | Unit | Data | |||||
Product mode | PGS-11 | PGS-24 | PGS-38 | |||||
1 | Rated voltage | kV | 11 | 24 | 38 | |||
6/10/11 | 15/17.5/20 | 33/36/38 | ||||||
2 | Rated frequency | Hz | 50/60 | 50/60 | 50/60 | |||
3 | Rated insulation level(The filling SF6 gas 0.07Mpa / 20 ° C) | (Lightning impulse withstand voltage) | relatively | kV | 75 | 125 | 185 | |
Fracture | 85 | 145 | 215 | |||||
Power frequency withstand voltage 1min | relatively | kV | 42 | 64 | 95 | |||
Fracture | 50 | 79 | 110 | |||||
4 | Insulation level of zero gauge pressure. | Power frequency withstand voltage 1min | kV | 30 | ||||
RP-pressure 1min | 30 | |||||||
The highest phase voltage 5min | 9 | |||||||
5 | Rated current | A | 630(400) | 630(400) | 630(400) | |||
6 | Rated breaking load current (0.07Mpa / 20 ° C) | A | 630(400) | 630(400) | 630(400) | |||
7 | breaking current under zero gauge pressure | A | 630(400) | 630(400) | 630(400) | |||
8 | peak withstand current | kA | 50 | 50 | 50 | |||
9 | Rated short time making current | kA | 50 | 50 | 50 | |||
11 | rated short time withstand current | KA/s | 20/4 | 20/4 | 20/4 | |||
12 | rated cable charging breaking current | A | 25 | 25 | 25 | |||
13 | rated line charging breaking current | A | 16 | 16 | 16 | |||
14 | rated closed-loop breaking current | A | 630(400) | 630(400) | 630(400) | |||
15 | exciting current | A | 21 | 21 | 21 | |||
16 | rated current breaking times | Times | ≥400 | ≥400 | ≥400 | |||
17 | rated working pressure | Mpa | 0.07 | 0.07 | 0.25 | |||
18 | Per-phase main circuit resistance | μΩ | ≤150 | ≤150 | ≤150 | |||
19 | relative gas leakage rate | year | ≤1% | ≤1% | ≤1% | |||
20 | SF6 gas moisture content | Factory transfer of value | ppm | ≤150 | ≤150 | ≤150 | ||
Switch running value | ppm | ≤300 | ≤300 | ≤300 | ||||
21 | operation of echanical stability | times | 6000 | 6000 | 6000 | |||
22 | rated operating voltage and auxiliary circuits rated voltage | V | DC 220/ 110/48/24 | DC 220/ 110/48/24 | DC 220/ 110/48/24 | |||
AC 220/110 | AC 220/110 | AC 220/110 | ||||||
23 | Weight | Type M | kg | 115 | 125 | 135 | ||
Type A | 135 | 145 | 155 | |||||
24 | institutions boxes and controller protection class | IP44 IP54 | ||||||
25 | Type of Mounting | The lifting type (suspended)/block (horizontal) |