Medium Voltage Vacuum Circuit Breaker
Model: MV VCB
Power: 12KV/630A
The 12KV Indoor Medium Voltage Vacuum Circuit Breaker (VCB) is designed for indoor switchgear in 12KV power systems. It serves as a reliable protection and control unit for power grid equipment and industrial and mining enterprises. This circuit breaker is suitable for switching various loads of different natures, frequent operations, and multiple interruptions of short-circuit currents.
Description
The 12KV Indoor Medium Voltage Vacuum Circuit Breaker (VCB) is designed for indoor switchgear in 12KV power systems. It serves as a reliable protection and control unit for power grid equipment and industrial and mining enterprises. This circuit breaker is suitable for switching various loads of different natures, frequent operations, and multiple interruptions of short-circuit currents.
Key Features:
- The VCB utilizes solid-sealed pole poles from international brands for its primary part, and the vacuum interrupter and main conductive circuit parts are solid-sealed into a whole, offering enhanced protection against impact, dust, and condensation.
- The breaker demonstrates strong environmental adaptability, significantly reducing operation and maintenance costs.
- The operating mechanism is integrated with the circuit breaker body and has been verified through type tests.
- It boasts an E2 electrical life and M12 mechanical life, ensuring long-lasting performance and reliability.
Environmental Requirements:
- Ambient temperature: Highest temperature +40°C, Lowest temperature -15°C.
- Environmental humidity: Daily average relative humidity ≤ 95%, Monthly average relative humidity: ≤ 90%, Daily average vapor pressure ≤ 22×10^-3MPa, Monthly average vapor pressure ≤ 1.8×10^-3MPa.
- Altitude: Not more than 1000m.
- The earthquake intensity does not exceed 8 degrees.
- The surrounding air should not be significantly polluted by dust, smoke, corrosive and/or flammable gas, steam, or salt spray.
Note: If the operating environment exceeds the specified conditions above, it is essential to consult with the manufacturer for appropriate arrangements.
Item | Unit | Data | |||
1 | Rated voltage | 12 | |||
2 | Maximum working voltage | kv | 12 | ||
3 | Rated current | A | 630 1250 | 630 1250 | |
4 | Rated short-circuit break current | kA | 20/25 | 31.5 | |
5 | Rated short-circuit close current (peak value) | kA | 50/63 | 80 | |
6 | Rated withstand current (peak value) | kA | 50/63 | 80 | |
7 | 4S Rated little withstand current | kA | 20/25 | 31.5 | |
8 | Rated insulation level | Industrial frequency withstand voltage | kA | 42/48 | |
Thunder impulse
withstand voltage |
75/85 | ||||
9 | Rated operation order | Off-0.3S on and off-180S-on and off | |||
10 | Mechanical life | times | 10000 | ||
11 | Rated short-circuit current break and close time | times | 50 | ||
12 | Speak and move organization amount assign the current
of the floodgate(DC) |
V | AC.DC.110,220 | ||
13 | Speak and move organization amount equal to the current
of the floodgate(DC) |
V | AC.DC 110,220 | ||
14 | Switching distance of the contact | mm | >11 | ||
15 | Ultra journey(touches the head spring and compress length) | mm | 4+/-0.5 | ||
16 | Three-phase breaking into shut
floodgate sex of the same period |
ms | <2 | ||
17 | Touch the head and shut a floodgate of time of bouncing | ms | <2 | ||
18 | Average speed of breaking brake | m/s | 0.9~1.7 | ||
19 | Average speed of closing brake | m/s | 0.6~1.0 | ||
20 | Time of breaking brake | Operate it under the
voltage highest |
s | <0.05 | |
Operate it under the
voltage lowest |
<0.08 | ||||
21 | Time of closing brake | s | <0.1 | ||
22 | Each the resistance of main return circuit | u Ω | <45 | ||
23 | Allowance abrasion cumulated thickness
of the moving and stationary contact |
mm | 3 |